Balboa Hl Error Code

Contents

We suggest you check back here often, as we will be regularly updating this info. Sn3 = Open or shorted sensor ( heater disabled). If this is the case, simply unplug, and plug in the sensor a few times to clean it. If the pressure switch cannot be recalibrated, replace it. http://waspsoft.com/error-code/balboa-error-code-oh.html

By doing that the pump came on but only for like 2 seconds until the OH kicked in and disabled everything. Back to Top rSA or CK SANITIZER Message Time to Check "Sanitizer Level Reminder" (rSA).Appears Every 7 Days*. Spa has shut down. Ecn = Spa operating in Economy Mode.

Balboa Sns Error Code

If HL comes on when it gets to hot then something may infact be wrong. OHS = Overheat. Call Balboa Technical Service for Additional Help if this Spa is Installed in a country Other Than the United States or Canada.Ground Fault Circuit Interrupter (GFCI) Trip Feature Top Previous NextAlong

  • If an ozonator is present, disconnect it.
  • Back to Top rtr or TREAT WOOD Message Time to "Treat Wood Reminder" (rtr).Appears Every 180 Days*.
  • Plug in a new transformer.
  • Make sure that they are open.• Clean the filter(s), waterline skimmer and footwell suction for any blockage..• In extremely hot weather, check for proper cabinet ventilation.• Check for excessive filter duration.
  • If there is Now a "CrC" or "CHKSUM FAIL" Error Message, contact your Dealer or Service Organization.
  • If the flow rate still seems less than normal with all jets and valves open, you may consider inspecting for broken valves (closed when they appear to be open), clogged impeller
  • Clean and Condition Spa Cover per Manufacturers Instructions.
  • Spa unusable.

How do I become a dealer? When the hot tub is in a filter cycle, make sure P1 low-speed is on. Recalibrate the pressure switch. Balboa High Limit Switch Location If there is Now a "rtC" or "RTC FAILURE" Real Time Clock Error Message, contact your Dealer or Service Organization.

Power on the spa must be cycled before the heater will function again. Arctic Spa Hl Error Code Lol Share this post Link to post Share on other sites christiffa25 0 Junior Member Members 0 38 posts Posted June 1, 2012 · Report post Ok hopefully final *update* Back to Top drn or DRAINING Message While in Standby Mode, "Drain" (drn) Mode has been Activated.The "Jets 1" Button has been Pressed while in the Standby Mode, and Pump 1 Make sure the pressure switch wire is connected to the proper circuit board connector.

That causes me some concern because HL should not be coming on during temp drop, that is counter productive.If the HL protects overheating, then when temperature is water drops drastically the Balboa Hot Tub Error Codes This is normal and is not an indication of an error. Not knowing what I was really doing decided to put all back together and leave well alone!! ILOC = Interlock failure - possible pump or ozone spike. (---) =Unknown water temperature. (Displays when first powered up after refill).

Arctic Spa Hl Error Code

Now Even after re-setting at the breaker when I attempt to turn the tub on it displays OH straight away and doesn't do anything. Back to Top OHH, HH, or HTR TEMP LMT SERVICE REQD Message There is an "Over Heated Heater" (OHH or HH) Condition.One of the Water Temp Sensors has detected 118°F (47.8°C) Balboa Sns Error Code F2 = 4 hours daily filtration F4 = 8 hours daily filtration F6 = 12 hours daily filtration FC = continuous filtration EasyPak C = Celsius CL = Current Time of Hl Error Code Hot Tub Heater disabled but the spa is operational.

Heat Related Pump Not Running.8. his comment is here These are similar to the Sn1 and Sn2 codes, signaled from the high limit or water temperature sensors. Disconnect the pressure switch wire from the circuit board. The low speed pump or circ pump will operate continuously until the temperature rises above 45° F. Balboa High Limit Sensor

Make sure that the water temperature displayed on the topside panel is at least 1 degree below the heater set temperature and set the control to standard mode. If water temperature drops 20ºF below set temperature, low speed pump and heater activates to bring temperature within 15º of set temperature. Back to Top Your cart is empty. http://waspsoft.com/error-code/balboa-error-code-sl.html My tub reverts to a default temp of 95 on power up.

To read the Current Water Temperature, either Change to Standard Heating Mode or turn On the Heating Related Pump, and wait at least 2 Minutes. Balboa Spa Control Manual Do not enter the water. Heater Start Up will begin again after about 1 Min.

Spa Builders Spa Side Error Codes Sn1 = Nonfunctional high temperature sensor.

To read the Current Water Temperature, either Change to Standard Heating Mode or turn On the Heating Related Pump, and wait at least 2 Minutes. All Reminder Messages can be Disabled through the Topside Panel Users Menu.* Note: The Balboa Default Interval is 30 Days, but some Spa Brands or Models may be Different. OH = Overheating, water over 112° F. Balboa Hot Tub Codes Sl Pumps and Blower can be turned ON and OFF to Remove any Air from the Heater.

Why does the GFCI trip immediately upon power up? th3/39 = On startup indicates water temperature less than 39° F. System will restart when temp. navigate here All Reminder Messages can be Disabled through the Topside Panel Users Menu.* Note: The Balboa Default Interval is 365 Days, but some Spa Brands or Models may be Different.

FL2 = Pressure switch problem. Share this post Link to post Share on other sites christiffa25 0 Junior Member Members 0 38 posts Posted May 24, 2012 · Report post Thanks for reply "count" Apologies Underneath the spa, check that all valves are open (handles up). PSoC = Pressure switch open with circulating pump.

Contact your Dealer or Service Organization. If a given pump has two speeds, press its Jets button a second time to set it to high speed. (High speed should be used for priming.)- When you have verified System will Auto Reset when Water Temp is below 108°F (42.2°C). Water temperature has reached 118ºF.

Your cache administrator is webmaster. No action is necessary. Back to Top Snb, Sb, or SENSOR B SERVICE REQD Message "Sensor B" (Snb or Sb) is Not Operating Correctly.The Sensor Connected to the "Sens.B" Connector on the System Board may I turned power back on and it fired up.

Balboa Control Manufacturer Scroll past Common Error Codes for: What common codes actually mean and what you can check prior to scheduling service Common Spa or Hot Tub Error Common Spa Panel Messages - - - or - - Message - - F, - - C, or - - Message CFE or CONFIG ERROR Message CrC or CHKSUM FAIL Message